Aarrow Fires Acorn 4 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Piecyk opalany drewnem Aarrow Fires Acorn 4. Aarrow Fires Acorn 4 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Aarrow Fires Ltd
The Fireworks
Bridport
Dorset, DT6 3BE
Great Britain
Tel. (44) 01308 427234
Fax. (44) 01308 423441
www.aarrowfires.com
Acorn
Multifuel Stoves
Operating & Installation Manual
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
The Acorn 4 Multifuel Stove (shown above)
Rev 2
Part No: AFS1126
March 2004
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - Multifuel Stoves

Aarrow Fires LtdThe FireworksBridportDorset, DT6 3BEGreat BritainTel. (44) 01308 427234Fax. (44) 01308 423441www.aarrowfires.comAcornMultifuel StovesO

Strona 2

MULTIFUEL GRATEGRATEThe grates in the Acorn Multifuel units comprise aseries of reciprocating cast iron bars seated on apivoted "comb". All

Strona 3 - CONTENTS

FITTING THE FLUE OUTLET ANDHOT PLATEThe flue outlet spigot is found inside the appliance.It is removed by turning clockwise.Smear a very thin layer of

Strona 4 - 4 Acorn Multifuel Stoves

Due to the gradual introduction of EuropeanChimney Standards chimneys will be specifiedaccording to their performance designation asdefined in BS EN 1

Strona 5 - THE PRINCIPLE OF THE FIRE

Acorn Multifuel Stoves 13INSTALLATIONTYPICAL REAR FLUE OUTLET

Strona 6 - CHECK LIST

14 Acorn Multifuel StovesINSTALLATIONTYPICAL METAL INSULATED CHIMNEY SYSTEMTO BE INSTALLED TO THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCEWITH

Strona 7 - TECHNICAL DATA

ADD IN BOILERSAcorn 4 & 5 multifuel stoves offer the option of aslab boiler, which occupies the position of the rearfirebox liner panels.Fitting:•

Strona 8 - GENERAL PRECAUTIONS

16 Acorn Multifuel StovesINSTALLATION INSTRUCTIONS The expansion tank should have a capacity of atleast 7 % of the system's water capacity. The c

Strona 9 - FIXING KIT

Fig. 7 Fully Closed Fig. 8 Fully OpenEven when all the slots are completely shut a"bleed" of secondary air will be maintainedensuring th

Strona 10 - INSTALLATION

Fig. 11b fitting new glass•Replace the two lower retaining clips and nuts.•Replace the upper airwash cover and nuts. Do notover-tighten the nuts as da

Strona 11 - FLUES AND CHIMNEYS

Approval does not cover the use of other fuelseither alone or mixed with a suitable fuel listedabove, nor does it cover instructions for use ofother f

Strona 12

Congratulations on your choice of an Aarrow Stove.More than 20 years experience has been put into the development ofour Acorn Multifuel to ensure ulti

Strona 13 - TYPICAL REAR FLUE OUTLET

In the morning•Open the air control fully until embers begin to glow brightly and place pieces of fuel on the fire until it is well established.WARNIN

Strona 14

Acorn Multifuel Stoves 21OPERATING INSTRUCTIONSCLEANINGImportant; Under some circumstances soot can quicklybuild up on the throat plate and adjacent a

Strona 15 - WATER CONNECTIONS

22 Acorn Multifuel StovesFINAL CHECK LISTCHECKLISTHearths, Fireplaces, Flues and chimneysThis checklist is to ensure hearths, fireplaces, flues and ch

Strona 16 - AIR INLET CONTROLS

Acorn Multifuel Stoves 23PARTS LIST1. Integral FrontBrace/ RetainerAFS1101AFS1086AFS001AFS064AFS008AFS1141AFS009A2. Throat Plate3. Grate Bar4. Hot Pla

Strona 17 - OPERATING INSTRUCTIONS

24 Acorn Multifuel StovesPARTS LIST8. Liner SetAFS1090AFS1092AFS1094AFS1095AFS1096AFS047AFS10979. Side Liner10. Back Liner Set 11. GlassReplacement Ki

Strona 18 - FUEL TYPES

Acorn Multifuel Stoves 25PARTS LIST15. Fire Door RopeKit Complete withDoor Rope Glue.AFS048AFS1099AFS1100AFS204AFS99716. Main DoorAssembly Completewit

Strona 19 - EXTENDED BURNING

GuaranteeOnce again we would like to thank you for buyingan Aarrow fire. When you buy an Aarrow Fire, you are not onlybuying a first class appliance -

Strona 20 - OVER-FIRING

Should you have any questions about your Acorn Multifuel Stove that is not covered in this manual pleasecontact your Aarrow retailer.Please keep all r

Strona 21 - ANNUAL MAINTENANCE

FINAL FACTORY CHECK LISTQUALITYFINISHPARTSFLUE OUTLETHOT PLATEFRONT INTEGRAL BRACEGRATEFIREBOX LININGSTHROAT PLATEAIR WASHDOOR CATCHESASH PANOPERATING

Strona 22 - CHECKLIST

INTRODUCTION PageSafety Notices 5The Principle of the Fire 5Check List 6Technical Data 7INSTALLATION PageGener

Strona 23 - PARTS LIST

WARNINGTO ALL MULTIFUEL USERSPETROLEUM COKESOME OF WHOSE BRAND NAMES ARE"CALCO", "PETROCOKE" OR "WONDERCO"MUST NOT BE BU

Strona 24

Acorn Multifuel Stoves 5INTRODUCTIONSAFETYA fireguard conforming to BS 8423: 2002 shouldbe used in the presence of children and old/orinfirm people. I

Strona 25

Inside the appliance you should find the following:6 Acorn Multifuel StovesCHECK LISTPart Description & Visual Aid(not to scale)Acorn 4 MultifuelQ

Strona 26 - Guarantee

Acorn Multifuel Stoves 7TECHNICAL DATARoom Min/MaxRoom Heater Only Output (kW)1- 4.5TECHNICAL DATA Acorn 4MultifuelRoom Heater with Domestic HotWater

Strona 27 - SERVICE RECORD

8 Acorn Multifuel StovesINSTALLATIONGENERAL PRECAUTIONSNote - All installations must conform to theappropriate building regulations. The Building Regu

Strona 28 - I’ve checked it

FIREBOX LINER PANELSThe Acorn Multifuel stoves have reflective liners tothe sides and back. The throat plate sits on top ofthe side and rear panels. T

Komentarze do niniejszej Instrukcji

Brak uwag